Ink illustration of detector streaks peeling away from a smooth halo of light around Earth.

To See Earth's Hydrogen Halo, Carruthers Must Subtract Its Own Instrument Effects

A new study describes the Carruthers GCI calibration pipeline, which removes instrument effects from raw telemetry. In simulations, the corrected L1B images are unbiased within the field of view with residual errors of 2.6% for the narrow-field imager and 1.1% for the wide-field imager, though the radiation scaling factor still needs on-orbit testing.

Nov 11, 2026

At the Earth-Sun L1 Lagrange point, in a halo orbit around a gravitational balance spot on the Sun-Earth line, NASA's Carruthers Geocorona Observatory looks back toward Earth. Its target is not a planet or a star but a faint ultraviolet signal: Lyman-alpha light at 1216 angstroms, emitted by hydrogen in Earth's exosphere, the outermost layer of the atmosphere. Lyman-alpha is the brightest feature of the geocorona, the hydrogen halo around Earth. To image the faint outer reaches of that halo, Carruthers must detect a signal that can be swamped by the spacecraft's own instrument effects. A calibration study describes the algorithms used to retrieve and remove those effects from raw telemetry on orbit.

Column-wise bias and blocked-filter speckle must come out first

The primary payload, the GeoCoronal Imager, has two co-aligned photometric imagers. The narrow-field imager has a 3.6-degree field of view for high spatial resolution near Earth's limb. The wide-field imager has an 18-degree field of view for the broader, dimmer exosphere. Both use microchannel plate intensified CMOS detectors. In simple terms, an ultraviolet photon strikes a potassium bromide photocathode, starts an electron avalanche in the microchannel plate, and the resulting charge is converted to green light and read by a silicon detector. That amplification makes faint light measurable. It also lets the instrument add its own signatures to every frame.

The paper lists detector voltage bias, thermal dark current, particle radiation, flat-field variations and optical distortion as instrument effects. It also describes registration steps for image orientation differences. In raw images, detector bias is the dominant feature. Each detector is controlled by two field-programmable gate arrays, one for the top half and one for the bottom, so the bias is split into two halves and is constant along vertical columns. The bias changes with temperature. Occasional calibration frames would miss the instantaneous bias in a science image, so the team retrieves it from electrically dark rows included in every readout and subtracts it image by image.

Dark current and anomalous pixels follow a similar path. The sensor will operate between about 17 and 20 degrees Celsius, so dark current is expected to be non-negligible. The team uses images taken through a blocking filter that admits no light. After bias removal, any pixel more than five standard deviations from the image mean is flagged as anomalous. A short blocked exposure is scheduled every three hours, and the nearest quiet-time blocked frame is subtracted. The paper states that this prioritizes removal of anomalous pixels over perfectly precise dark-current subtraction. Transient anomalous pixels that appear in only one image cannot be corrected. The paper calls them rare and acceptable.

The radiation correction depends on a ratio orbit must test

Solar energetic particles can strike the microchannel plate or the silicon detector directly. The signal from particles hitting the silicon active pixel sensor is called APS radiation. The team estimates it from pixels outside the field of view or in shielded rows. Microchannel plate radiation is confined to the field of view in blocked images, so it cannot be measured directly in normal science images. The team derives a scaling factor between the APS radiation rate and the microchannel plate radiation rate, then uses that factor to estimate the plate contribution in science images.

This step assumes the two radiation rates track the same incoming particle flux. The paper says this assumption cannot be tested in a laboratory and lacks precedent. Its validity must be assessed during on-orbit operations. The algorithm also uses a quiet-time threshold. If the background mean is below that threshold, radiation subtraction is skipped. If the mean is above it, the algorithm subtracts APS radiation and an estimate of microchannel plate radiation scaled by the flat-field.

The simulations put the radiation component in context. Radiation retrieval underestimates the radiation signal by about 2.3 percent. The retrieved radiation signal has standard deviations of 17 percent for the narrow-field imager and 8.5 percent for the wide-field imager. Even in an S3 solar storm, a strong storm on NOAA's space weather scale, radiation is only about 10 percent of the total signal. After correction for both radiation types, the simulated science-filter images remain centered at zero with a 1.3 percent standard deviation within the field of view.

Simulated L1B images stay within 2.6 percent and 1.1 percent

Flat-field correction addresses pixel-to-pixel sensitivity differences. No uniformly illuminated target exists naturally in orbit. The spacecraft will slew to the diffuse interplanetary hydrogen glow and take four open-filter exposures separated by 90-degree rolls. Stacking the rotated images averages out spatial gradients. Bright stars, the Moon and planets are masked. A persistence check keeps true detector features from being mistaken for celestial sources. The flat-field is normalized and divided out of science images.

The full pipeline from raw telemetry to L1B images is validated with a synthetic numerical image generator, while pre-launch laboratory data validated individual algorithms. L1B images are instrument-effect-corrected images. In simulations using the baseline LyaN science filter, the errors within the field of view are centered at zero with standard deviations of about 2.6 percent for the narrow-field imager and 1.1 percent for the wide-field imager. Simulated flat-field retrieval is also centered at zero with standard deviations of 3 percent and 1.43 percent. The paper says both meet NASA's 5 percent accuracy requirement. Its analytical flat-field validation does not guarantee that target in S4 and above storm conditions.

These 2.6 percent and 1.1 percent figures come from simulations, not from a long record of on-orbit science. The paper reports that the algorithms are now operationally processing flight data. It does not report on-orbit validation of those residual errors. The radiation scaling factor remains a key open question. The pipeline's success is also measured in residual error, not in the final hydrogen maps. L1B images are input to later steps that remove photon backgrounds and establish absolute calibration. For the faint outer exosphere, the instrument's own electronic fingerprints have to be understood and subtracted before the hydrogen halo can be mapped.